{"title":"Fire Door Hardware \u0026 Components","description":"\u003cp\u003eFire door \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-components-and-hardware-requirements\" title=\"Fire Door Components \u0026amp; Hardware Requirements\"\u003ehardware and components\u003c\/a\u003e include the essential parts that ensure a door assembly functions correctly in the event of a fire. This collection covers key items such as hinges, closers, seals, and related components required to maintain compliance and support effective fire door operation.\u003c\/p\u003e","products":[{"product_id":"fire-door-gap-gauge-door-tolerance-check","title":"Fire Door Gap Gauge - Door Tolerance Check","description":"\u003cp\u003eAccurately checking fire door gaps is one of the most common parts of a \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-inspection-checklist\" title=\"Fire door inspection checklist\"\u003efire door inspection\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003eFire Door Gap Gauge\u003c\/strong\u003e is a simple tool used to measure the gap between the door leaf and frame, helping you identify whether \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-gap-size-requirements\" title=\"Fire door gap size requirements\"\u003egaps fall within commonly expected tolerances\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFire Risk Assessments (FRA) frequently identify excessive or inconsistent gaps as defects. Using a gauge removes guesswork and allows checks to be carried out consistently.\u003c\/p\u003e\n\u003ch3\u003eWhat it helps you check\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eside and head gaps\u003c\/li\u003e\n\u003cli\u003ethreshold gaps\u003c\/li\u003e\n\u003cli\u003econsistency around the door\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy a gap gauge is useful\u003c\/h3\u003e\n\u003cp\u003eGap size is difficult to assess visually.\u003c\/p\u003e\n\u003cp\u003eA gauge allows you to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003echeck gaps quickly during routine inspections\u003c\/li\u003e\n\u003cli\u003eidentify doors that may require adjustment\u003c\/li\u003e\n\u003cli\u003esupport consistent inspection records\u003c\/li\u003e\n\u003cli\u003eavoid relying on subjective judgement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical use\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eroutine fire door checks\u003c\/li\u003e\n\u003cli\u003einspection programmes\u003c\/li\u003e\n\u003cli\u003epre-FRA internal checks\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-remedial-actions-after-fra\" title=\"Fire door remedial actions after an FRA\"\u003econfirming remedial works\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eInsert the gauge between the door leaf and frame at multiple points to check for consistency.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eGap tolerances may vary depending on the door design, seals and installation. Always consider the Fire Risk Assessment and door specification when interpreting results.\u003c\/p\u003e","brand":"Fire Door Requirements","offers":[{"title":"Default Title","offer_id":52423156171094,"sku":"F0201-S","price":9.99,"currency_code":"GBP","in_stock":false}]},{"product_id":"intumescent-fire-door-seal-fire-only","title":"Intumescent Fire Door Seal - Fire Only (FD30)","description":"\u003cp\u003eIntumescent strips are used to help maintain the fire-resisting performance of a fire door by sealing gaps around the door leaf \u003ca title=\"Intumescent strips regulations\" href=\"https:\/\/firedoorrequirements.co.uk\/pages\/intumescent-strips-regulations\"\u003ewhen exposed to heat\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eDuring a fire, the material expands, helping to close the gap between the door and frame and support the integrity of the door assembly.\u003c\/p\u003e\n\u003cp\u003eDamaged, missing or incorrect seals are commonly identified during Fire Risk Assessments (FRA), particularly where doors have been altered, repaired or subject to wear over time.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003efire-only intumescent strip\u003c\/strong\u003e is typically used where fire resistance is required without additional smoke control.\u003c\/p\u003e\n\u003ch3\u003eWhen it is typically required\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eexisting seals are damaged, worn or missing\u003c\/li\u003e\n\u003cli\u003efire doors are being remediated following inspection\u003c\/li\u003e\n\u003cli\u003eincorrect seal types have been fitted\u003c\/li\u003e\n\u003cli\u003efire resistance needs to be reinstated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat it does\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eexpands when exposed to heat\u003c\/li\u003e\n\u003cli\u003ehelps \u003ca title=\"Fire door gap size requirements\" href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-gap-size-requirements\"\u003eseal gaps between the door leaf and frame\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003esupports the fire-resisting performance of the door assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUnlike combined seals, this product does \u003cstrong\u003enot include a smoke brush or smoke seal element\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eImportant\u003c\/h3\u003e\n\u003cp\u003eSeal type, size and installation method should align with the fire door design and any available certification or specification.\u003c\/p\u003e\n\u003cp\u003eFire-only seals may not be suitable where smoke control is required. Where there is uncertainty, the Fire Risk Assessment and door specification should be considered before installation.\u003c\/p\u003e\n\u003ch3\u003eTypical use\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ereplacing damaged or missing intumescent strips\u003c\/li\u003e\n\u003cli\u003eremedial works following inspection findings\u003c\/li\u003e\n\u003cli\u003emaintaining fire door integrity where smoke control is not specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication note\u003c\/h3\u003e\n\u003cp\u003eDesigned for installation into existing rebates in the door leaf or frame.\u003c\/p\u003e\n\u003cp\u003eIf the door does not have rebates, a surface-mounted seal system may be required instead.\u003c\/p\u003e","brand":"Fire Door Requirements","offers":[{"title":"10mm \/ Brown","offer_id":52699289878870,"sku":"F04F-30-10-B","price":9.99,"currency_code":"GBP","in_stock":true},{"title":"10mm \/ White","offer_id":52699289813334,"sku":"F04F-30-10-W","price":9.99,"currency_code":"GBP","in_stock":true},{"title":"15mm \/ Brown","offer_id":52699289911638,"sku":"F04F-30-15-B","price":9.99,"currency_code":"GBP","in_stock":true},{"title":"15mm \/ White","offer_id":52699289846102,"sku":"F04F-30-15-W","price":9.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/7976\/5846\/files\/intumescent-strip-fire-only_cover.jpg?v=1772839253"},{"product_id":"intumescent-seal-combined","title":"Intumescent Fire Door Seal - Fire \u0026 Smoke Combined (FD30)","description":"\u003cp\u003eCombined intumescent and smoke seals are used to help restrict the spread of fire and smoke by sealing gaps around a fire door.\u003c\/p\u003e\n\u003cp\u003eDamaged, missing or incorrect seals are one of the most common issues identified during Fire Risk Assessments (FRAs).\u003c\/p\u003e\n\u003cp\u003eThis \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/intumescent-strips-regulations\" title=\"Intumescent strips regulations\"\u003ecombined seal\u003c\/a\u003e is typically used where both fire resistance and smoke control are required.\u003c\/p\u003e\n\u003ch3\u003eWhen it is typically required\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eseals are damaged, worn or missing\u003c\/li\u003e\n\u003cli\u003esmoke control is part of the door’s intended function\u003c\/li\u003e\n\u003cli\u003eincorrect seal types have been fitted\u003c\/li\u003e\n\u003cli\u003eremedial works are required following inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat it does\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eexpands under heat to \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-gap-size-requirements\" title=\"Fire door gap size requirements\"\u003ehelp seal gaps\u003c\/a\u003e (intumescent function)\u003c\/li\u003e\n\u003cli\u003ehelps restrict smoke movement in normal conditions (smoke seal)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant\u003c\/h3\u003e\n\u003cp\u003eSeal type, size and installation method should align with the fire door design and any available certification or specification.\u003c\/p\u003e\n\u003cp\u003eThis product should not be used as a generic substitute where the correct seal type is unknown.\u003c\/p\u003e\n\u003ch3\u003eTypical use\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eremedial works following FRA findings\u003c\/li\u003e\n\u003cli\u003ereplacement of damaged seals\u003c\/li\u003e\n\u003cli\u003ereinstating missing seal sections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication note\u003c\/h3\u003e\n\u003cp\u003eDesigned for installation into existing rebates in the door leaf or frame.\u003c\/p\u003e","brand":"Fire Door Requirements","offers":[{"title":"10mm \/ Brown","offer_id":52699282768214,"sku":"F04C-30-10-B","price":14.99,"currency_code":"GBP","in_stock":true},{"title":"10mm \/ White","offer_id":52699282702678,"sku":"F04C-30-10-W","price":14.99,"currency_code":"GBP","in_stock":true},{"title":"15mm \/ Brown","offer_id":52699282800982,"sku":"F04C-30-15-B","price":14.99,"currency_code":"GBP","in_stock":true},{"title":"15mm \/ White","offer_id":52699282735446,"sku":"F04C-30-15-W","price":14.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/7976\/5846\/files\/intumescent-strip-fire-and-smoke-combined_cover.jpg?v=1772839104"},{"product_id":"fire-rated-door-hinges","title":"Fire-Rated Door Hinges (Set of 3)","description":"\u003cp\u003e\u003cstrong\u003eSet of three heavy-duty stainless steel fire door hinges for replacement or remedial work where existing hinges are worn, damaged or unsuitable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHinges support the door leaf, help maintain consistent gaps and contribute to correct closing behaviour. Problems with hinges can lead to dropped or misaligned doors, uneven gaps and poor self-closing performance.\u003c\/p\u003e\n\u003cp\u003eThese \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-hinges-requirements\" title=\"Fire door hinges requirements\"\u003efire-rated door hinges\u003c\/a\u003e are intended for use on suitable timber and steel fire doors where compatible with the specific door assembly.\u003c\/p\u003e\n\u003ch2\u003eWhen replacement may be needed\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ehinges are loose, worn or damaged\u003c\/li\u003e\n\u003cli\u003efixings are missing or no longer secure\u003c\/li\u003e\n\u003cli\u003ethe door has dropped or become misaligned\u003c\/li\u003e\n\u003cli\u003eexisting hinges appear unsuitable for the fire door\u003c\/li\u003e\n\u003cli\u003ea fire door inspection identifies hardware concerns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey product details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eset of 3 ball-bearing hinges\u003c\/li\u003e\n\u003cli\u003estainless steel finish\u003c\/li\u003e\n\u003cli\u003eGrade 13 under BS EN 1935\u003c\/li\u003e\n\u003cli\u003eCE marked and Certifire rated\u003c\/li\u003e\n\u003cli\u003esuitable for timber and steel fire doors, subject to the door specification\u003c\/li\u003e\n\u003cli\u003emaximum stated door mass: 120kg\u003c\/li\u003e\n\u003cli\u003ehinge size: 102mm × 76mm × 3mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy hinges matter\u003c\/h2\u003e\n\u003cp\u003eHinge condition can directly affect door alignment, \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-gap-size-requirements\" title=\"Fire door gap size requirements\"\u003egap consistency\u003c\/a\u003e and self-closing performance. Replacing unsuitable or worn hinges can form part of remedial work following an inspection.\u003c\/p\u003e\n\u003ch2\u003eImportant\u003c\/h2\u003e\n\u003cp\u003eFire door hinges must be suitable for the particular door assembly and required performance. Where the correct specification is uncertain, appropriate advice should be obtained before replacement.\u003c\/p\u003e","brand":"Fire Door Requirements","offers":[{"title":"Default Title","offer_id":52939206426966,"sku":"F05H-01","price":24.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/7976\/5846\/files\/fire-door-hinge.png?v=1789743035"},{"product_id":"fire-door-threshold-seal-drop-down-surface-mounted","title":"Fire Door Threshold Seal (Drop-Down, Surface-Mounted)","description":"\u003cp\u003e\u003cstrong\u003eSurface-mounted drop-down smoke seal for fire doors, designed as a practical retrofit solution where the gap beneath the door needs to be reduced for smoke control.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-threshold-seal-requirements\" title=\"Fire Door Threshold Seal Requirements\"\u003efire door threshold seal\u003c\/a\u003e mounts to the face of the door, so no routing or rebating is required. When the door closes, a plunger mechanism lowers the rubber sealing gasket towards the floor. When the door opens, the seal retracts.\u003c\/p\u003e\n\u003ch2\u003eWhen a drop-down threshold seal may be suitable\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ewhere the \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-gap-size-requirements\" title=\"Fire door gap size requirements\"\u003egap beneath a fire door is excessive\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ewhere smoke control is required as part of the door assembly\u003c\/li\u003e\n\u003cli\u003efor retrofit remedial work where routing or rebating is not practical\u003c\/li\u003e\n\u003cli\u003ewhere a surface-mounted solution is preferred\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003esurface-mounted drop-down smoke seal\u003c\/li\u003e\n\u003cli\u003ealuminium body with rubber sealing gasket\u003c\/li\u003e\n\u003cli\u003emaximum drop: 14mm\u003c\/li\u003e\n\u003cli\u003esuitable for gaps up to approximately 14mm\u003c\/li\u003e\n\u003cli\u003eavailable in 830mm and 930mm lengths\u003c\/li\u003e\n\u003cli\u003ecan be trimmed by up to approximately 150mm to suit the door width\u003c\/li\u003e\n\u003cli\u003esuitable for push or pull side installation\u003c\/li\u003e\n\u003cli\u003esupplied with fixing screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow the seal works\u003c\/h2\u003e\n\u003cp\u003eAs the door closes, the plunger contacts the frame and activates the drop-down mechanism, lowering the gasket towards the floor to help restrict smoke, draughts and air movement beneath the door. The seal retracts again when the door is opened.\u003c\/p\u003e\n\u003ch2\u003eImportant\u003c\/h2\u003e\n\u003cp\u003eThreshold seals should be selected to suit the door design, gap size and required performance. This product is intended to support smoke control at the threshold and should not be used as a substitute where the correct fire door specification or required remedial work is unknown.\u003c\/p\u003e","brand":"Fire Door Requirements","offers":[{"title":"830mm","offer_id":53109958738262,"sku":"F04T-SM-0830","price":49.99,"currency_code":"GBP","in_stock":true},{"title":"930mm","offer_id":53109958771030,"sku":"F04T-SM-0930","price":49.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/7976\/5846\/files\/threshold-seal-surface-mounted.png?v=1789729859"},{"product_id":"fire-rated-door-closer-adjustable","title":"Fire-Rated Door Closer (Adjustable, EN 2–4)","description":"\u003cp\u003e\u003cstrong\u003eAdjustable overhead fire door closer for internal fire doors, with EN 2–4 power adjustment plus adjustable closing speed and latching action.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA correctly specified \u003ca href=\"https:\/\/firedoorrequirements.co.uk\/pages\/fire-door-self-closer-requirements\" title=\"Fire Door Self-Closer Requirements\"\u003efire door closer\u003c\/a\u003e helps the door return automatically to the fully closed position after use. This model is suited to replacement or remedial work where a closer is missing, faulty or no longer closes and latches the door correctly.\u003c\/p\u003e\n\u003ch2\u003eTypically required when\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ea fire door does not self-close fully\u003c\/li\u003e\n\u003cli\u003ethe door fails to latch correctly\u003c\/li\u003e\n\u003cli\u003ean existing closer is missing, faulty or ineffective\u003c\/li\u003e\n\u003cli\u003eremedial work is required following a fire door inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eadjustable power size: EN 2–4\u003c\/li\u003e\n\u003cli\u003esuitable for doors up to approximately 1100mm wide \/ 80kg\u003c\/li\u003e\n\u003cli\u003eadjustable closing speed\u003c\/li\u003e\n\u003cli\u003eadjustable latching action\u003c\/li\u003e\n\u003cli\u003eCE marked to EN 1154\u003c\/li\u003e\n\u003cli\u003euniversal fixing for push or pull side installation\u003c\/li\u003e\n\u003cli\u003emaximum opening angle approximately 180°\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat it does\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ereturns the door to the closed position automatically\u003c\/li\u003e\n\u003cli\u003eallows closing speed to be adjusted\u003c\/li\u003e\n\u003cli\u003eprovides adjustable latching action to help the door engage correctly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eImportant\u003c\/h2\u003e\n\u003cp\u003eThe closer must be correctly specified, installed and adjusted to suit the door size, weight and use. Fire performance depends on the complete fire door assembly, not the closer alone.\u003c\/p\u003e","brand":"Fire Door Requirements","offers":[{"title":"Default Title","offer_id":53110000976214,"sku":"F05C-01","price":74.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/7976\/5846\/files\/fire-door-closer.png?v=1789743055"}],"url":"https:\/\/firedoorrequirements.co.uk\/collections\/hardware-components.oembed","provider":"Fire Door Requirements","version":"1.0","type":"link"}